Schneider Electric DOL Starter, DOL, 1.5 kW, 415 V ac, 3 Phase, IP65

Pre-order available (0 In Stock) pcs
Price:
£ 0
Units Per Unit Price
  • secure-payment
  • visa
  • american-express
  • master-card
  • opayo

Product Specification

Product Attributes
Power Rating 1.5 kW
Motor Starter Type DOL
Voltage Rating 415 V ac
Phase 3
IP Rating IP65
Number of Poles 3P
Motor Starter Functionality Automatic
Overall Length 160mm
Enclosure Yes
Overall Width 78mm
Series LE1
Overall Depth 108mm
Better World Product Yes
Better World Verification Green Premium
3D Model https://www.traceparts.com/els/rs-components/en/api/viewer/3d?SupplierID=RS_COMPONENTS&PartNumber=148908&DisplayLogo=False

More Information

Schneider Electric LE1 Series DOL Starter, 1.5 kW - LE1M35N710 This DOL starter is designed for efficient electric motor control across various applications. It has a power rating of 1.5kW and is suitable for three-phase operations, providing automatic functionality that promotes operational efficiency. With an IP65 rating, it offers strong protection against dust and water ingress, making it suitable for different industrial conditions. Its Green Premium certification highlights its commitment to environmental performance. Features & Benefits • Supports 1.5kW power at 415V AC for effective operation
• IP65 rated for protection in harsh conditions
• Automatic motor starter for consistent operation and efficiency
• Includes thermal overload relay for added safety
• Features contactor with earth and neutral terminals for enhanced safety
• Local signalling aids in status monitoring Applications • Suitable for controlling three-phase electric motors in industrial settings
• Ideal for equipment requiring automatic motor functions
• Effective for applications within standard utilisation categories
• Commonly used in environments needing high ingress protection What is the operating temperature range for efficient performance? The operational temperature range is -5 to 40°C, ensuring suitability for functionality. How does one adjust the thermal protection settings? Adjustments to thermal protection can be made directly on the unit for optimal safety. What types of cable entry options are available? Various cable entry configurations, including ISO and Pg types, are available for flexible installations. Can it be used in standard environments? Yes, it is suitable for standard environmental conditions, providing reliability. What certifications does it comply with for safety and environmental standards? It complies with UKCA regulations and aligns with Green Premium sustainability standards.

Similar Products

Loading products...